# PT Details Expected Plan Dates PT Performed at PT Scheme Type Accreditation Status Action
Ongoing PT Plan
1 Plan Id: GLMV/P1110/PTC/01/24
Product Description: Vernier Calliper (Digital Vernier Caliper having the range of 300 mm with 0.01 mm least count.)
Test Parameter:
External Jaws Measurement
  • Test Points: 20, 50, 100, 150, 200, 300 mm
    CMC Requirement: coarser than 0.00804 mm
Test Method: Comparison Method as per IS 16491 Part -1: 2016 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Nov-2025
Registration End Date: Feb-2026
Participant Premises Sequential Yes
2 Plan Id: GLMV/P1318/PTC/01/14
Product Description: Force Proving Instrument - Load Cell
Test Parameter:
Force
    Test Method: Comparison method as per IS 4169 or technically equivalent method.
    (*) PT round will be completed subjected to at least 1 participants only.
    Registration Start Date: Dec-2025
    Registration End Date: Mar-2026
    Participant Premises Sequential No
    3 Plan Id: GLMV/P1280/PTC/01/11
    Product Description: Vacuum Gauge (Vacuum Gauge has range from -1.0 bar to 0 bar.)
    Test Parameter:
    Vacuum Measurement (Error)
    • Test Points: -0.1, -0.3, -0.5, -0.7, -0.9 bar
      CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
    Test Method: Comparison Method as per DKD R-6-1 or Technically Equivalent Method
    (*) PT round will be completed subjected to at least 1 participants only.
    Registration Start Date: Dec-2025
    Registration End Date: Feb-2026
    Participant Premises Sequential No
    4 Plan Id: GLMV/P1313/PTC/01/10
    Product Description: Tachometer (Contact & Non-Contact) (Tachometer has range from 0 to 99999 with the resolution 0.01 rpm upto 100, from 100 to 1000 resolution is 0.1 rpm and from 1000 above 1 rpm resolution.)
    Test Parameter:
    Speed
    • Test Points: 50, 150, 250, 550, 950 rpm
    Test Method: Comparison Method or Technically Equivelent method
    (*) PT round will be completed subjected to at least 1 participants only.
    Registration Start Date: Dec-2025
    Registration End Date: Mar-2026
    Participant Premises Sequential No
    5 Plan Id: GLMV/P1307/PTC/01/9
    Product Description: Internal Micrometer
    Test Parameter:
    Linear Measurement
    • Test Points: 10, 15, 20, 25 mm
      CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
    Test Method: Comparison Method as per IS 2967 or Technically Equivalent Method
    (*) PT round will be completed subjected to at least 1 participants only.
    Registration Start Date: Nov-2025
    Registration End Date: Jan-2026
    Participant Premises Sequential No
    6 Plan Id: GLMV/P1268/PTC/01/8
    Product Description: RTD without Indicator (Range: -38 to 250°C)
    Test Parameter:
    Temperature
    • Test Points: 35, 60, 110, 150, 180 deg C
      CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
    Test Method: Comparison Method as per DKD-R-5-1 or Technically Equivalent Method
    (*) PT round will be completed subjected to at least 5 participants only.
    Registration Start Date: Oct-2025
    Registration End Date: Dec-2025
    Participant Premises Sequential No
    7 Plan Id: GLMV/P1139/PTC/01/5
    Product Description: Hot Air Oven (Hot Air Oven having resolution 0.1°C for the range 250°C.)
    Test Parameter:
    Temperature Measurement
    • Test Points: 40, 80, 120, 160, 190 deg C
      CMC Requirement: coarser than 0.66 deg C
    Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
    (*) PT round will be completed subjected to at least 5 participants only.
    Registration Start Date: Sep-2025
    Registration End Date: Jan-2026
    PTP Premises Sequential Yes
    8 Plan Id: GLMV/P1283/PTC/01/4
    Product Description: Plain Plug Gauge (Plain Plug Gauge has a range from 0.5mm to 150mm.)
    Test Parameter:
    Diameter
      Test Method: Comparison method as per IS:3455 / IS: 6137 / IS: 6244 / IS: 6246 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 2 participants only.
      Registration Start Date: Dec-2025
      Registration End Date: Mar-2026
      Participant Premises Sequential No
      9 Plan Id: GLMV/P1285/PTC/01/3
      Product Description: Centrifuge (Centrifuge has the range of 4500 rpm.)
      Test Parameter:
      RPM
        Test Method: Comparison Method
        (*) PT round will be completed subjected to at least 5 participants only.
        Registration Start Date: Nov-2025
        Registration End Date: Feb-2026
        PTP Premises Sequential No
        10 Plan Id: GLMV/P1286/PTC/01/2
        Product Description: Motor (Motor has the range of 3000rpm.)
        Test Parameter:
        RPM
          Test Method: Comparison Method
          (*) PT round will be completed subjected to at least 2 participants only.
          Registration Start Date: Oct-2025
          Registration End Date: Jan-2026
          PTP Premises Sequential No
          11 Plan Id: GLMV/P1122/PTC/01/2024/2
          Product Description: Pressure Gauge
          Test Parameter:
          Pressure Measurement
          • Test Points: 14, 21, 35, 49, 70 bar
            CMC Requirement: coarser than 0.041 bar
          Test Method: Comparison Method as per DKD R-6-1 or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 7 participants only.
          Registration Start Date: Sep-2025
          Registration End Date: Dec-2025
          Participant Premises Sequential Yes
          12 Plan Id: GLMV/P1151/PTC/01/2024/1
          Product Description: Slump Cone
          Test Parameter:
          Top Diameter Measurement
          • Test Points: 100 mm
            CMC Requirement: coarser than 0.0120 mm
          Bottom Diameter Measurement
          • Test Points: 200 mm
            CMC Requirement: coarser than 0.0120 mm
          Height Measurement
          • Test Points: 300 mm
            CMC Requirement: coarser than 0.0120 mm
          Test Method: Comparison Method as per IS 7320: 1974 or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 5 participants only.
          Registration Start Date: Oct-2025
          Registration End Date: Feb-2026
          Participant Premises Sequential Yes
          13 Plan Id: GLMV/P1121/PTC/01/2024/1
          Product Description: Standard Glass Scale (Precision Glass Scale Range: 200mm, Least Count: 0.1mm)
          Test Parameter:
          Linear Measurement
          • Test Points: 20, 40, 80, 120, 150 mm
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison Method
          (*) PT round will be completed subjected to at least 7 participants only.
          Registration Start Date: Oct-2025
          Registration End Date: Jan-2026
          Participant Premises Sequential Yes
          14 Plan Id: GLMV/P1127/PTC/01/2024/1
          Product Description: Measuring Tape (Range: 3000mm, Least Count: 1mm)
          Test Parameter:
          Linear Measurement
          • Test Points: 100, 500, 1000, 2000, 2500 mm
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison Method as per IS 1269 (Part 2) : 1997 RA 2018 or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 8 participants only.
          Registration Start Date: Oct-2025
          Registration End Date: Feb-2026
          Participant Premises Sequential Yes
          15 Plan Id: GLMV/P1128/PTC/01/2023/1
          Product Description: Taper Scale (Taper scale has the range of 15 mm with 0.1 mm least count.)
          Test Parameter:
          Linear Measurement
          • Test Points: 3, 6, 9, 12, 14 mm
            CMC Requirement: coarser than 0.0068 mm
          Test Method: Comparison Method
          (*) PT round will be completed subjected to at least 7 participants only.
          Registration Start Date: Oct-2025
          Registration End Date: Dec-2025
          Participant Premises Sequential Yes
          16 Plan Id: GLMV/P1148/PTC/01/2023/1
          Product Description: Accelerated Curing Tank (ACT) (Range: Up to 100°C & Resolution: 0.1°C )
          Test Parameter:
          Temperature Error Measurement
          • Test Points: 30.0, 45.0, 60.0, 75.0, 90.0 deg C
            CMC Requirement: coarser than 0.66 deg C
          Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 5 participants only.
          Registration Start Date: Oct-2025
          Registration End Date: Jan-2026
          PTP Premises Sequential Yes
          17 Plan Id: GLMV/P1149/PTC/01/2023/1
          Product Description: Curing Tank (Range: Up to 100 °C, Resolution: 0.1°C)
          Test Parameter:
          Temperature Measurement
          • Test Points: 25.0, 26.0, 27.0, 29.0, 30.0 deg C
            CMC Requirement: coarser than 0.66 deg C
          Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 5 participants only.
          Registration Start Date: Jul-2025
          Registration End Date: Jan-2026
          PTP Premises Sequential Yes
          18 Plan Id: GLMV/P1150/PTC/01/2023/1
          Product Description: Coating Thickness Gauge (Range: 0.999mm, Resolution: 0.0001mm)
          Test Parameter:
          Thickness Measurement
          • Test Points: 0.049, 0.102, 0.499, 0.996 mm
            CMC Requirement: coarser than 0.0026 mm
          Test Method: Comparison Method or Technically equivalent Method
          (*) PT round will be completed subjected to at least 7 participants only.
          Registration Start Date: Oct-2025
          Registration End Date: Jan-2026
          Participant Premises Sequential Yes
          19 Plan Id: GLMV/P1152/PTC/01/2023/1
          Product Description: Templates
          Test Parameter:
          Linear Measurement
          • Test Points: 200 mm
            CMC Requirement: coarser than 0.011 mm
          Test Method: Comparison Method
          (*) PT round will be completed subjected to at least 8 participants only.
          Registration Start Date: Oct-2025
          Registration End Date: Feb-2026
          Participant Premises Sequential Yes
          20 Plan Id: GLMV/P1154/PTC/01/2023/2
          Product Description: Ultrasonic Thickness Gauge (Ultrasonic Thickness Gauge)
          Test Parameter:
          Thickness Measurement
          • CMC Requirement: coarser than 0.0026 mm
          Test Method: Comparison Method or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 7 participants only.
          Registration Start Date: Aug-2025
          Registration End Date: Dec-2025
          Participant Premises Sequential Yes
          21 Plan Id: GLMV/P1140/PTC/01/2023/1
          Product Description: Muffle Furnace (Digital Muffle Furnace having the range of 1200 deg C with resolution 0.1°C up to 999.9°C & 1°C from 1000-1200°C.)
          Test Parameter:
          Temperature Measurement
          • Test Points: 300.0, 500.0, 700.0, 900.0 deg C
            CMC Requirement: coarser than 2.67 deg C
          Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 5 participants only.
          Registration Start Date: Jul-2025
          Registration End Date: Dec-2025
          PTP Premises Sequential Yes
          22 Plan Id: GLMV/P1137/PTC/01/2023/1
          Product Description: Angle Graticule (having LC: 1.0 degree)
          Test Parameter:
          Angle Measurement
          • Test Points: 15, 30, 45, 60, 75 deg
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison Method or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 7 participants only.
          Registration Start Date: Mar-2025
          Registration End Date: Jan-2026
          Participant Premises Sequential Yes
          23 Plan Id: GLMV/P1116/PTC/01/2023/1
          Product Description: Cube Mould (Size:- 150*150*150 mm.)
          Test Parameter:
          Linear Measurement: Length
          • Test Points: 150 mm
            CMC Requirement: coarser than 0.0109 mm
          Linear Measurement: Width
          • Test Points: 150 mm
            CMC Requirement: coarser than 0.0109 mm
          Linear Measurement: Height
          • Test Points: 150 mm
            CMC Requirement: coarser than 0.0109 mm
          Test Method: Comparison Method as per IS 10086: 2021 IS 9669 or Technically Equivalent Method
          (*) PT round will be completed subjected to at least 5 participants only.
          Registration Start Date: Sep-2025
          Registration End Date: Dec-2025
          Participant Premises Sequential Yes
          24 Plan Id: GLMV/P1133/PTC/01/2023/1
          Product Description: Thermometer
          Test Parameter:
          Temperature Measurement
          • Test Points: -20, -5, 20, 50, 100 deg C
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison Method
          (*) PT round will be completed subjected to at least 7 participants only.
          Registration Start Date: Jan-2025
          Registration End Date: Dec-2025
          Participant Premises Sequential Yes
          Upcoming PT Plan
          1 Plan Id: GLMV/P1321/PTC/01/23
          Product Description: Cylindrical Measuring Pin / Measuring Pin (Cylindrical Measuring Pin has the range of 10 mm.)
          Test Parameter:
          Linear Measurement / Dia
          • Test Points: 10 mm
            CMC Requirement: coarser than 0.00109 mm
          Test Method: Com parison method technically equivalent method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Apr-2026
          Registration End Date: 30-Jun-2026
          Participant Premises Sequential No
          2 Plan Id: GLMV/P1320/PTC/01/22
          Product Description: Plain Ring Gauge / Setting Ring Gauge (Plain ring gauge has the range up to 25 mm.)
          Test Parameter:
          Linear Measurement
          • Test Points: 05, 25 mm
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Com parison method or Technically equivalent method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-May-2026
          Registration End Date: 01-Jun-2026
          Participant Premises Sequential No
          3 Plan Id: GLMV/P1281/PTC/01/21
          Product Description: Sound Level Meter (Sound Level Meter has the range from 40 dBA to 130 dBA with the resolution of 0.1dBA.)
          Test Parameter:
          Sound Measurement
          • Test Points: 80, 100 dB
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison Method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Apr-2026
          Registration End Date: 01-Jun-2026
          Participant Premises Sequential No
          4 Plan Id: GLMV/P1311/PTC/01/20
          Product Description: Impact Charpy (Impact Charpy machine has the range from 0.1 Joule to 300 Joule.)
          Test Parameter:
          Impact Energy
          • Test Points: 50, 100, 150, 200, 250 J
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison as per ISO 148-2 / IS 1575 Part-2 or Technically equivalent method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Mar-2026
          Registration End Date: 30-Apr-2026
          PTP Premises Sequential No
          5 Plan Id: GLMV/P1273/PTC/01/19
          Product Description: RH Indicator / Indicator of Humidity Chamber
          Test Parameter:
          Humidity
          • Test Points: 45, 60, 75, 90 %RH
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Temperature
          • Test Points: 25, 35 deg C
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison method as per DKD –R5-7 or Technically Equivalent Method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Mar-2026
          Registration End Date: 31-May-2026
          PTP Premises Sequential No
          6 Plan Id: GLMV/P1272/PTC/01/18
          Product Description: Infrared thermometer (Infrared Thermometer has the range from -40 °C to 800 °C with the resolution of 0.1 °C.)
          Test Parameter:
          Temperature
          • Test Points: -10, 50, 100, 150, 200 deg C
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison method as per MSL technical guide 22, VDI/VDE 355 Part 4.3 or Technically Equivalent Method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Apr-2026
          Registration End Date: 31-May-2026
          Participant Premises Sequential No
          7 Plan Id: GLMV/P1276/PTC/01/17
          Product Description: Thermo Hygrometer (Thermohygrometer has range for temperature from -10 °C to 50 °C and for Humidity from 10%RH to 99%RH. )
          Test Parameter:
          Humidity
          • Test Points: 25, 55, 80 %RH
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Temperature
          • Test Points: 30.0, 50.0 deg C
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison Method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Feb-2026
          Registration End Date: 30-Apr-2026
          Participant Premises Sequential No
          8 Plan Id: GLMV/P1309/PTC/01/16
          Product Description: Volumetric Glassware (Pipette / burette) (Pipette has the range up to 10 ml. )
          Test Parameter:
          Volume
          • Test Points: 2, 4, 6, 8, 10 ml
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison as per ASTM E 287-02 or IS 1977 or Technically Equivalent Method.
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Mar-2026
          Registration End Date: 30-Apr-2026
          Participant Premises Sequential No
          9 Plan Id: GLMV/P1310/PTC/01/15
          Product Description: Hydrometer
          Test Parameter:
          Density / Specific Gravity
          • Test Points: 1.100, 1.200
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison method as per IS 3104 or Technically Equivalent method.
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Feb-2026
          Registration End Date: 30-Apr-2026
          Participant Premises Sequential No
          10 Plan Id: GLMV/P1317/PTC/01/13
          Product Description: Turque wrench / Torque Tool
          Test Parameter:
          Torque
            Test Method: Com parison method as per ISO 6789 or technically equivalent method.
            (*) PT round will start subjected to at least 1 participants registration only.
            Registration Start Date: 01-Jan-2026
            Registration End Date: 31-Mar-2026
            Participant Premises Sequential No
            11 Plan Id: GLMV/P1153/PTC/02/12
            Product Description: Thermocouple Without Indicator (Range: 200°C to 1500°C, Resolution: 0.001°C, S-Type.)
            Test Parameter:
            Temperature Measurement
            • Test Points: 280, 350, 500, 650, 800 deg C
              CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
            Test Method: Comparison Method as per ASTM E 220- 13/ EURAMET cg-8 or Technically Equivalent Method.
            (*) PT round will start subjected to at least 1 participants registration only.
            Registration Start Date: 01-Jan-2026
            Registration End Date: 01-Mar-2026
            Participant Premises Sequential No
            (*) mark terms and condition will apply.

            Contact Details of PT Scheme:
            Name: Mr. Vivek Kumar (PT Coordinator)
            Contact No.: 8097457925
            Email: ptcoordinator@globallab.co.in

            Note: