# PT Details Expected Plan Dates PT Performed at PT Scheme Type Accreditation Status Action
Ongoing PT Plan
1 Plan Id: GLMV/P1307/PTC/01/9
Product Description: Internal Micrometer
Test Parameter:
Linear Measurement
  • Test Points: 10, 15, 20, 25 mm
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method as per IS 2967 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 1 participants only.
Registration Start Date: Nov-2025
Registration End Date: Jan-2026
Participant Premises Sequential No
2 Plan Id: GLMV/P1268/PTC/01/8
Product Description: RTD without Indicator (Range: -38 to 250°C)
Test Parameter:
Temperature
  • Test Points: 35, 60, 110, 150, 180 deg C
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method as per DKD-R-5-1 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Oct-2025
Registration End Date: Dec-2025
Participant Premises Sequential No
3 Plan Id: GLMV/P1138/PTC/01/7
Product Description: Universal Testing Machine (Class-1 having the range up to 1200kN with 0.06kN resolution.)
Test Parameter:
Force Measurement: Relative Indication Error
  • Test Points: 100, 200, 400, 600, 800 kN
    CMC Requirement: coarser than 0.25 %
Force Measurement: Relative Repeatability Error
  • Test Points: 100, 200, 400, 600, 800 kN
    CMC Requirement: coarser than 0.25 %
Test Method: Comparison Method as per IS 1828 Part-1: 2022 or Technically Equivalent Method (In Compression Mode)
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Sep-2025
Registration End Date: Dec-2025
PTP Premises Sequential Yes
4 Plan Id: GLMV/P1134/PTC/01/6
Product Description: Standard Weight (E2 Class Weights of Range (0.5g, 5g, 10g, 100g and 200g).)
Test Parameter:
Mass Measurement
  • Test Points: 0.5, 5, 10, 100, 200 g
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method as per OIML R111 -1 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Sep-2025
Registration End Date: Nov-2025
Participant Premises Sequential Yes
5 Plan Id: GLMV/P1139/PTC/01/5
Product Description: Hot Air Oven (Hot Air Oven having resolution 0.1°C for the range 250°C.)
Test Parameter:
Temperature Measurement
  • Test Points: 40, 80, 120, 160, 190 deg C
    CMC Requirement: coarser than 0.66 deg C
Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Sep-2025
Registration End Date: Jan-2026
PTP Premises Sequential Yes
6 Plan Id: GLMV/P1285/PTC/01/3
Product Description: Centrifuge (Centrifuge has the range of 4500 rpm.)
Test Parameter:
RPM
    Test Method: Comparison Method
    (*) PT round will be completed subjected to at least 5 participants only.
    Registration Start Date: Nov-2025
    Registration End Date: Feb-2026
    PTP Premises Sequential No
    7 Plan Id: GLMV/P1286/PTC/01/2
    Product Description: Motor (Motor has the range of 3000rpm.)
    Test Parameter:
    RPM
      Test Method: Comparison Method
      (*) PT round will be completed subjected to at least 2 participants only.
      Registration Start Date: Oct-2025
      Registration End Date: Jan-2026
      PTP Premises Sequential No
      8 Plan Id: GLMV/P1117/PTC/01/2024/2
      Product Description: Digital Weighing Balance (Range: 220g, Resolution 0.0001g, Class-1)
      Test Parameter:
      Linearity Error
      • Test Points: 1, 10, 50, 100, 150, 180 g
        CMC Requirement: coarser than 0.00018 g
      Test Method: OIML R-76-01 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Sep-2025
      Registration End Date: Nov-2025
      PTP Premises Sequential Yes
      9 Plan Id: GLMV/P1122/PTC/01/2024/2
      Product Description: Pressure Gauge
      Test Parameter:
      Pressure Measurement
      • Test Points: 14, 21, 35, 49, 70 bar
        CMC Requirement: coarser than 0.041 bar
      Test Method: Comparison Method as per DKD R-6-1 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Sep-2025
      Registration End Date: Dec-2025
      Participant Premises Sequential Yes
      10 Plan Id: GLMV/P1110/PTC/01/2024/1
      Product Description: Vernier Calliper (Digital Vernier Caliper having the range of 300mm with 0.01mm least count.)
      Test Parameter:
      External Jaws Measurement
      • Test Points: 50, 100, 150, 200, 250 mm
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison Method as per IS 16491 Part -1: 2016 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: May-2025
      Registration End Date: Nov-2025
      Participant Premises Sequential Yes
      11 Plan Id: GLMV/P1147/PTC/01/2024/2
      Product Description: Profile Projector (Range for Linear Measurement at X-axis -200 mm, Y axis- 100 mm, LC: 0.001 mm & Magnification: 10 X.)
      Test Parameter:
      Linear Measurement (X Axis)
      • Test Points: 10, 25, 50, 75, 90 mm
        CMC Requirement: coarser than 0.00179 mm
      Linear Measurement (Y Axis)
      • Test Points: 10, 25, 50, 75, 90 mm
        CMC Requirement: coarser than 0.00179 mm
      Magnification
      • Test Points: 10 X
        CMC Requirement: coarser than 0.063 %
      Test Method: Comparison Method as per JIS B 7184: 2021 or Technically Equivalent method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Apr-2025
      Registration End Date: Nov-2025
      PTP Premises Sequential Yes
      12 Plan Id: GLMV/P1151/PTC/01/2024/1
      Product Description: Slump Cone
      Test Parameter:
      Top Diameter Measurement
      • Test Points: 100 mm
        CMC Requirement: coarser than 0.0120 mm
      Bottom Diameter Measurement
      • Test Points: 200 mm
        CMC Requirement: coarser than 0.0120 mm
      Height Measurement
      • Test Points: 300 mm
        CMC Requirement: coarser than 0.0120 mm
      Test Method: Comparison Method as per IS 7320: 1974 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Oct-2025
      Registration End Date: Feb-2026
      Participant Premises Sequential Yes
      13 Plan Id: GLMV/P1114/PTC/01/2024/1
      Product Description: Flakiness Gauge
      Test Parameter:
      Linear Measurement: length
      • Test Points: Slot Size: 12.5 - 10.0, 16.0 - 12.5, 40 - 31.5, 50 - 40 mm
        CMC Requirement: coarser than 0.0113 mm
      Linear Measurement: Thickness
      • Test Points: Slot Size: 34.8-35.2, 39.8-40.2, 79.8-80.2, 89.8-90.2 mm
        CMC Requirement: coarser than 0.0113 mm
      Test Method: Comparison Method as per IS 2386 Part-1: 1963 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Sep-2025
      Registration End Date: Dec-2025
      Participant Premises Sequential Yes
      14 Plan Id: GLMV/P1129/PTC/01/2024/1
      Product Description: Lever Type Dial Indicator (having the range up to 0.8mm with 0.01mm resolution.)
      Test Parameter:
      Linear Measurement
      • Test Points: 0.015, 0.025, 0.035, 0.045, 0.055 mm
        CMC Requirement: coarser than 0.0019 mm
      Test Method: Comparison Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Sep-2025
      Registration End Date: Nov-2025
      Participant Premises Sequential Yes
      15 Plan Id: GLMV/P1135/PTC/01/2024/1
      Product Description: Slip Gauge (Grade '0')
      Test Parameter:
      Linear Measurement
      • Test Points: 5.1, 10.3, 20.2, 50, 100 mm
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison Method as per IS 2984: 2003 RA 2019 / ISO 3650 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Sep-2025
      Registration End Date: Nov-2025
      Participant Premises Sequential Yes
      16 Plan Id: GLMV/P1121/PTC/01/2024/1
      Product Description: Standard Glass Scale (Precision Glass Scale Range: 200mm, Least Count: 0.1mm)
      Test Parameter:
      Linear Measurement
      • Test Points: 20, 40, 80, 120, 150 mm
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Oct-2025
      Registration End Date: Jan-2026
      Participant Premises Sequential Yes
      17 Plan Id: GLMV/P1127/PTC/01/2024/1
      Product Description: Measuring Tape (Range: 3000mm, Least Count: 1mm)
      Test Parameter:
      Linear Measurement
      • Test Points: 100, 500, 1000, 2000, 2500 mm
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison Method as per IS 1269 (Part 2) : 1997 RA 2018 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 8 participants only.
      Registration Start Date: Oct-2025
      Registration End Date: Feb-2026
      Participant Premises Sequential Yes
      18 Plan Id: GLMV/P1126/PTC/01/2023/1
      Product Description: Linear Variable Differential Transformers (LVDT) (LVDT has the range of 0 to 25 mm with 0.001mm resolution.)
      Test Parameter:
      Linear Measurement
      • Test Points: 5.1, 10.3, 12.9, 17.6, 20.2 mm
        CMC Requirement: coarser than 0.0016 mm
      Test Method: Comparison Method as per ASTM F 2537-06 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Sep-2025
      Registration End Date: Nov-2025
      Participant Premises Sequential Yes
      19 Plan Id: GLMV/P1128/PTC/01/2023/1
      Product Description: Taper Scale (Taper scale has the range of 15 mm with 0.1 mm least count.)
      Test Parameter:
      Linear Measurement
      • Test Points: 3, 6, 9, 12, 14 mm
        CMC Requirement: coarser than 0.0068 mm
      Test Method: Comparison Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Oct-2025
      Registration End Date: Dec-2025
      Participant Premises Sequential Yes
      20 Plan Id: GLMV/P1148/PTC/01/2023/1
      Product Description: Accelerated Curing Tank (ACT) (Range: Up to 100°C & Resolution: 0.1°C )
      Test Parameter:
      Temperature Error Measurement
      • Test Points: 30.0, 45.0, 60.0, 75.0, 90.0 deg C
        CMC Requirement: coarser than 0.66 deg C
      Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Oct-2025
      Registration End Date: Jan-2026
      PTP Premises Sequential Yes
      21 Plan Id: GLMV/P1149/PTC/01/2023/1
      Product Description: Curing Tank (Range: Up to 100 °C, Resolution: 0.1°C)
      Test Parameter:
      Temperature Measurement
      • Test Points: 25.0, 26.0, 27.0, 29.0, 30.0 deg C
        CMC Requirement: coarser than 0.66 deg C
      Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Jul-2025
      Registration End Date: Jan-2026
      PTP Premises Sequential Yes
      22 Plan Id: GLMV/P1150/PTC/01/2023/1
      Product Description: Coating Thickness Gauge (Range: 0.999mm, Resolution: 0.0001mm)
      Test Parameter:
      Thickness Measurement
      • Test Points: 0.049, 0.102, 0.499, 0.996 mm
        CMC Requirement: coarser than 0.0026 mm
      Test Method: Comparison Method or Technically equivalent Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Oct-2025
      Registration End Date: Jan-2026
      Participant Premises Sequential Yes
      23 Plan Id: GLMV/P1152/PTC/01/2023/1
      Product Description: Templates
      Test Parameter:
      Linear Measurement
      • Test Points: 200 mm
        CMC Requirement: coarser than 0.011 mm
      Test Method: Comparison Method
      (*) PT round will be completed subjected to at least 8 participants only.
      Registration Start Date: Oct-2025
      Registration End Date: Feb-2026
      Participant Premises Sequential Yes
      24 Plan Id: GLMV/P1154/PTC/01/2023/2
      Product Description: Ultrasonic Thickness Gauge (Ultrasonic Thickness Gauge)
      Test Parameter:
      Thickness Measurement
      • CMC Requirement: coarser than 0.0026 mm
      Test Method: Comparison Method or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Aug-2025
      Registration End Date: Dec-2025
      Participant Premises Sequential Yes
      25 Plan Id: GLMV/P1140/PTC/01/2023/1
      Product Description: Muffle Furnace (Digital Muffle Furnace having the range of 1200 deg C with resolution 0.1°C up to 999.9°C & 1°C from 1000-1200°C.)
      Test Parameter:
      Temperature Measurement
      • Test Points: 300.0, 500.0, 700.0, 900.0 deg C
        CMC Requirement: coarser than 2.78 deg C
      Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Jul-2025
      Registration End Date: Dec-2025
      PTP Premises Sequential Yes
      26 Plan Id: GLMV/P1137/PTC/01/2023/1
      Product Description: Angle Graticule (having LC: 1.0 degree)
      Test Parameter:
      Angle Measurement
      • Test Points: 15, 30, 45, 60, 75 deg
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison Method or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Mar-2025
      Registration End Date: Jan-2026
      Participant Premises Sequential Yes
      27 Plan Id: GLMV/P1116/PTC/01/2023/1
      Product Description: Cube Mould (Size:- 150*150*150 mm.)
      Test Parameter:
      Linear Measurement: Length
      • Test Points: 150 mm
        CMC Requirement: coarser than 0.0109 mm
      Linear Measurement: Width
      • Test Points: 150 mm
        CMC Requirement: coarser than 0.0109 mm
      Linear Measurement: Height
      • Test Points: 150 mm
        CMC Requirement: coarser than 0.0109 mm
      Test Method: Comparison Method as per IS 10086: 2021 IS 9669 or Technically Equivalent Method
      (*) PT round will be completed subjected to at least 5 participants only.
      Registration Start Date: Sep-2025
      Registration End Date: Dec-2025
      Participant Premises Sequential Yes
      28 Plan Id: GLMV/P1133/PTC/01/2023/1
      Product Description: Thermometer
      Test Parameter:
      Temperature Measurement
      • Test Points: -20, -5, 20, 50, 100 deg C
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison Method
      (*) PT round will be completed subjected to at least 7 participants only.
      Registration Start Date: Jan-2025
      Registration End Date: Dec-2025
      Participant Premises Sequential Yes
      Upcoming PT Plan
      1 Plan Id: GLMV/P1281/PTC/01/21
      Product Description: Sound Level Meter (Sound Level Meter has the range from 40 dBA to 130 dBA with the resolution of 0.1dBA.)
      Test Parameter:
      Sound Measurement
      • Test Points: 80, 100 dB
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison Method
      (*) PT round will start subjected to at least 1 participants registration only.
      Registration Start Date: 01-Apr-2026
      Registration End Date: 01-Jun-2026
      Participant Premises Sequential No
      2 Plan Id: GLMV/P1311/PTC/01/20
      Product Description: Impact Charpy (Impact Charpy machine has the range from 0.1 Joule to 300 Joule.)
      Test Parameter:
      Impact Energy
      • Test Points: 50, 100, 150, 200, 250 J
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison as per ISO 148-2 / IS 1575 Part-2 or Technically equivalent method
      (*) PT round will start subjected to at least 1 participants registration only.
      Registration Start Date: 01-Mar-2026
      Registration End Date: 30-Apr-2026
      PTP Premises Sequential No
      3 Plan Id: GLMV/P1273/PTC/01/19
      Product Description: RH Indicator / Indicator of Humidity Chamber
      Test Parameter:
      Humidity
      • Test Points: 45, 60, 75, 90 %RH
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Temperature
      • Test Points: 25, 35 deg C
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison method as per DKD –R5-7 or Technically Equivalent Method
      (*) PT round will start subjected to at least 1 participants registration only.
      Registration Start Date: 01-Mar-2026
      Registration End Date: 31-May-2026
      PTP Premises Sequential No
      4 Plan Id: GLMV/P1272/PTC/01/18
      Product Description: Infrared thermometer (Infrared Thermometer has the range from -40 °C to 800 °C with the resolution of 0.1 °C.)
      Test Parameter:
      Temperature
      • Test Points: -10, 50, 100, 150, 200 deg C
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison method as per MSL technical guide 22, VDI/VDE 355 Part 4.3 or Technically Equivalent Method
      (*) PT round will start subjected to at least 1 participants registration only.
      Registration Start Date: 01-Apr-2026
      Registration End Date: 31-May-2026
      Participant Premises Sequential No
      5 Plan Id: GLMV/P1276/PTC/01/17
      Product Description: Thermo Hygrometer (Thermohygrometer has range for temperature from -10 °C to 50 °C and for Humidity from 10%RH to 99%RH. )
      Test Parameter:
      Humidity
      • Test Points: 25, 55, 80 %RH
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Temperature
      • Test Points: 30.0, 50.0 deg C
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison Method
      (*) PT round will start subjected to at least 1 participants registration only.
      Registration Start Date: 01-Feb-2026
      Registration End Date: 30-Apr-2026
      Participant Premises Sequential No
      6 Plan Id: GLMV/P1309/PTC/01/16
      Product Description: Volumetric Glassware (Pipette / burette) (Pipette has the range up to 10 ml. )
      Test Parameter:
      Volume
      • Test Points: 2, 4, 6, 8, 10 ml
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison as per ASTM E 287-02 or IS 1977 or Technically Equivalent Method.
      (*) PT round will start subjected to at least 1 participants registration only.
      Registration Start Date: 01-Mar-2026
      Registration End Date: 30-Apr-2026
      Participant Premises Sequential No
      7 Plan Id: GLMV/P1310/PTC/01/15
      Product Description: Hydrometer
      Test Parameter:
      Density / Specific Gravity
      • Test Points: 1.100, 1.200
        CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
      Test Method: Comparison method as per IS 3104 or Technically Equivalent method.
      (*) PT round will start subjected to at least 1 participants registration only.
      Registration Start Date: 01-Feb-2026
      Registration End Date: 30-Apr-2026
      Participant Premises Sequential No
      8 Plan Id: GLMV/P1318/PTC/01/14
      Product Description: Force Proving Instrument - Load Cell
      Test Parameter:
      Force
        Test Method: Comparison method as per IS 4169 or technically equivalent method.
        (*) PT round will start subjected to at least 1 participants registration only.
        Registration Start Date: 01-Dec-2025
        Registration End Date: 31-Mar-2026
        Participant Premises Sequential No
        9 Plan Id: GLMV/P1317/PTC/01/13
        Product Description: Turque wrench / Torque Tool
        Test Parameter:
        Torque
          Test Method: Com parison method as per ISO 6789 or technically equivalent method.
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Jan-2026
          Registration End Date: 31-Mar-2026
          Participant Premises Sequential No
          10 Plan Id: GLMV/P1153/PTC/02/12
          Product Description: Thermocouple Without Indicator (Range: 200°C to 1500°C, Resolution: 0.001°C, S-Type.)
          Test Parameter:
          Temperature Measurement
          • Test Points: 280, 350, 500, 650, 800 deg C
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison Method as per ASTM E 220- 13/ EURAMET cg-8 or Technically Equivalent Method.
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Jan-2026
          Registration End Date: 01-Mar-2026
          Participant Premises Sequential No
          11 Plan Id: GLMV/P1280/PTC/01/11
          Product Description: Vacuum Gauge (Vacuum Gauge has range from -1.0 bar to 0 bar.)
          Test Parameter:
          Vacuum Measurement (Error)
          • Test Points: -0.1, -0.3, -0.5, -0.7, -0.9 bar
            CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
          Test Method: Comparison Method as per DKD R-6-1 or Technically Equivalent Method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Dec-2025
          Registration End Date: 28-Feb-2026
          Participant Premises Sequential No
          12 Plan Id: GLMV/P1313/PTC/01/10
          Product Description: Tachometer (Contact & Non-Contact) (Tachometer has range from 0 to 99999 with the resolution 0.01 rpm upto 100, from 100 to 1000 resolution is 0.1 rpm and from 1000 above 1 rpm resolution.)
          Test Parameter:
          Speed
          • Test Points: 50, 150, 250, 550, 950 rpm
          Test Method: Comparison Method or Technically Equivelent method
          (*) PT round will start subjected to at least 1 participants registration only.
          Registration Start Date: 01-Dec-2025
          Registration End Date: 16-Mar-2026
          Participant Premises Sequential No
          13 Plan Id: GLMV/P1283/PTC/01/4
          Product Description: Plain Plug Gauge (Plain Plug Gauge has a range from 0.5mm to 150mm.)
          Test Parameter:
          Diameter
            Test Method: Comparison method as per IS:3455 / IS: 6137 / IS: 6244 / IS: 6246 or Technically Equivalent Method
            (*) PT round will start subjected to at least 2 participants registration only.
            Registration Start Date: 01-Dec-2025
            Registration End Date: 01-Mar-2026
            Participant Premises Sequential No
            (*) mark terms and condition will apply.

            Contact Details of PT Scheme:
            Name: Mr. Vivek Kumar (PT Coordinator)
            Contact No.: 8097457925
            Email: ptcoordinator@globallab.co.in