# PT Details Expected Plan Dates PT Performed at PT Scheme Type Accreditation Status Action
Ongoing PT Plan
1 Plan Id: GLMV/P1113/PTC/01/25
Product Description: Compression Testing Machine (Compression Testing Machine [Class-1] having the range up to 3000 kN with the resolution of 0.1 kN.)
Test Parameter:
Force Measurement: Relative Indication Error
  • Test Points: 200, 300, 400, 800, 900, 1200, 1800, 2100 kN
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Force Measurement: Relative Repeatability Error
  • Test Points: 200, 300, 400, 800, 900, 1200, 1800, 2100 kN
    CMC Requirement: coarser than 0.26 %
Test Method: Comparison Method as per IS 1828 Part-1: 2022 or Technically Equivalent Method (In Compression Mode)
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Feb-2026
Registration End Date: Jun-2026
PTP Premises Sequential Yes
2 Plan Id: VSC/P1147/PTC/01/1
Product Description: Profile Projector (Range for Linear Measurement at X-axis -200 mm, Y axis- 100 mm, LC: 0.001 mm & Magnification: 10 X.)
Test Parameter:
Linear Measurement (X Axis)
  • Test Points: 5.1, 22.7, 35.2, 45.2, 70.8, 110.3 mm
    CMC Requirement: coarser than 0.00179 mm
Linear Measurement (Y Axis)
  • Test Points: 5.1, 22.7, 35.2, 45.2, 70.8, 90 mm
    CMC Requirement: coarser than 0.00179 mm
Magnification
  • Test Points: 10 X
    CMC Requirement: coarser than 0.063 %
Test Method: Comparison Method as per JIS B 7184: 2021 or Technically Equivalent method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Jan-2026
Registration End Date: Jun-2026
PTP Premises Sequential Yes
3 Plan Id: GLMV/P1110/PTC/01/24
Product Description: Vernier Calliper (Digital Vernier Caliper having the range of 300 mm with 0.01 mm least count.)
Test Parameter:
External Jaws Measurement
  • Test Points: 50, 100, 150, 200, 250 mm
    CMC Requirement: coarser than 0.00837 mm
Test Method: Comparison Method as per IS 16491 Part -1: 2016 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Feb-2026
Registration End Date: Apr-2026
Participant Premises Sequential Yes
4 Plan Id: GLMV/P1276/PTC/01/17
Product Description: Thermo Hygrometer (Thermohygrometer has range for temperature from -10 °C to 50 °C and for Humidity from 10%RH to 99%RH. )
Test Parameter:
Humidity at Specified Temperature
  • Test Points: 40, 50, 60 %RH
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method
(*) PT round will be completed subjected to at least 3 participants only.
Registration Start Date: Feb-2026
Registration End Date: Apr-2026
Participant Premises Sequential No
5 Plan Id: GLMV/P1310/PTC/01/15
Product Description: Hydrometer
Test Parameter:
Density / Specific Gravity
  • Test Points: 1.100, 1.200
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison method as per IS 3104 or Technically Equivalent method.
(*) PT round will be completed subjected to at least 1 participants only.
Registration Start Date: Feb-2026
Registration End Date: Apr-2026
Participant Premises Sequential No
6 Plan Id: GLMV/P1138/PTC/01/7
Product Description: Universal Testing Machine (Class-1 having the range up to 1200kN with 0.06kN resolution.)
Test Parameter:
Force Measurement: Relative Indication Error
  • Test Points: 100, 200, 400, 600, 700 kN
    CMC Requirement: coarser than 0.26 %
Force Measurement: Relative Repeatability Error
  • Test Points: 100, 200, 400, 600, 700 kN
    CMC Requirement: coarser than 0.26 %
Test Method: Comparison Method as per IS 1828 Part-1: 2022 or Technically Equivalent Method (In Compression Mode)
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Jan-2026
Registration End Date: Jun-2026
PTP Premises Sequential Yes
7 Plan Id: GLMV/P1134/PTC/01/6
Product Description: Standard Weight (E2 Class Weights of Range (0.5g, 5g, 10g, 100g and 200g).)
Test Parameter:
Mass Measurement
  • Test Points: 0.5, 5, 10, 100, 200 g
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method as per OIML R111 -1 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Feb-2026
Registration End Date: Jun-2026
Participant Premises Sequential Yes
8 Plan Id: GLMV/P1139/PTC/01/5
Product Description: Hot Air Oven (Hot Air Oven having resolution 0.1°C for the range 250°C.)
Test Parameter:
Temperature Measurement
  • Test Points: 40, 80, 120, 160, 190 deg C
    CMC Requirement: coarser than 0.66 deg C
Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Jan-2026
Registration End Date: Jun-2026
PTP Premises Sequential Yes
9 Plan Id: GLMV/P1139/PTC/01/1
Product Description: Hot Air Oven (having the range of 250°C with 0.1°C L.C.)
Test Parameter:
Temperature Measurement
  • Test Points: 40, 80, 120, 160, 190 deg C
    CMC Requirement: coarser than 0.63 deg C
Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Mar-2026
Registration End Date: Jul-2026
PTP Premises Sequential Yes
10 Plan Id: GLMV/P1122/PTC/01/2024/3
Product Description: Pressure Gauge (Hydraulic Digital Pressure Gauge Range: 70bar, Resolution: 0.01bar)
Test Parameter:
Pressure Measurement
  • Test Points: 14, 21, 35, 49, 70 bar
    CMC Requirement: coarser than 0.043 bar
Test Method: Comparison Method as per DKD R-6-1 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 7 participants only.
Registration Start Date: Jan-2026
Registration End Date: Jun-2026
Participant Premises Sequential Yes
11 Plan Id: GLMV/P1122/PTC/01/2024/2
Product Description: Pressure Gauge
Test Parameter:
Pressure Measurement
  • Test Points: 14, 21, 35, 49, 70 bar
    CMC Requirement: coarser than 0.041 bar
Test Method: Comparison Method as per DKD R-6-1 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 7 participants only.
Registration Start Date: Sep-2025
Registration End Date: Jun-2026
Participant Premises Sequential Yes
12 Plan Id: GLMV/P1147/PTC/01/2024/2
Product Description: Profile Projector (Range for Linear Measurement at X-axis -200 mm, Y axis- 100 mm, LC: 0.001 mm & Magnification: 10 X.)
Test Parameter:
Linear Measurement (X Axis)
  • Test Points: 10.3, 25, 50, 75, 90 mm
    CMC Requirement: coarser than 0.00179 mm
Linear Measurement (Y Axis)
  • Test Points: 10.3, 25, 50, 75, 90 mm
    CMC Requirement: coarser than 0.00179 mm
Magnification
  • Test Points: 10 X
    CMC Requirement: coarser than 0.063 %
Test Method: Comparison Method as per JIS B 7184: 2021 or Technically Equivalent method
(*) PT round will be completed subjected to at least 7 participants only.
Registration Start Date: Apr-2025
Registration End Date: May-2026
PTP Premises Sequential Yes
13 Plan Id: GLMV/P1151/PTC/01/2024/1
Product Description: Slump Cone
Test Parameter:
Top Diameter Measurement
  • Test Points: 100 mm
    CMC Requirement: coarser than 0.0120 mm
Bottom Diameter Measurement
  • Test Points: 200 mm
    CMC Requirement: coarser than 0.0120 mm
Height Measurement
  • Test Points: 300 mm
    CMC Requirement: coarser than 0.0120 mm
Test Method: Comparison Method as per IS 7320: 1974 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Oct-2025
Registration End Date: Apr-2026
Participant Premises Sequential Yes
14 Plan Id: GLMV/P1115/PTC/01/2024/1
Product Description: Elongation Gauge
Test Parameter:
Linear Measurement: Length
  • Test Points: Slot size: 10.0- 6.3, 20.0 - 16.0, 25.0 - 20.0, 40.0 - 31.5 mm
    CMC Requirement: coarser than 0.0146 mm
Test Method: Comparison Method as per IS 2386 Part-1: 1963 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Nov-2025
Registration End Date: Apr-2026
Participant Premises Sequential Yes
15 Plan Id: GLMV/P1114/PTC/01/2024/1
Product Description: Flakiness Gauge
Test Parameter:
Linear Measurement: length
  • Test Points: Slot Size: 12.5 - 10.0, 16.0 - 12.5, 40 - 31.5, 50 - 40 mm
    CMC Requirement: coarser than 0.0113 mm
Linear Measurement: Thickness
  • Test Points: Slot Size: 34.8-35.2, 39.8-40.2, 79.8-80.2, 89.8-90.2 mm
    CMC Requirement: coarser than 0.0113 mm
Test Method: Comparison Method as per IS 2386 Part-1: 1963 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Dec-2025
Registration End Date: Apr-2026
Participant Premises Sequential Yes
16 Plan Id: GLMV/P1135/PTC/01/2024/1
Product Description: Gauge Block / Slip Gauge (Grade '0')
Test Parameter:
Linear Measurement
  • Test Points: 5.1, 10.3, 20.2, 50, 100 mm
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method as per IS 2984: 2003 RA 2019 / ISO 3650 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Dec-2025
Registration End Date: Apr-2026
Participant Premises Sequential Yes
17 Plan Id: GLMV/P1121/PTC/01/2024/1
Product Description: Standard Glass Scale (Precision Glass Scale Range: 200mm, Least Count: 0.1mm)
Test Parameter:
Linear Measurement
  • Test Points: 20, 40, 80, 120, 150 mm
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method
(*) PT round will be completed subjected to at least 7 participants only.
Registration Start Date: Oct-2025
Registration End Date: Jun-2026
Participant Premises Sequential Yes
18 Plan Id: GLMV/P1127/PTC/01/2024/1
Product Description: Measuring Tape (Range: 3000mm, Least Count: 1mm)
Test Parameter:
Linear Measurement
  • Test Points: 100, 500, 1000, 2000, 2500 mm
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method as per IS 1269 (Part 2) : 1997 RA 2018 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 8 participants only.
Registration Start Date: Oct-2025
Registration End Date: Jul-2026
Participant Premises Sequential Yes
19 Plan Id: GLMV/P1123/PTC/01/2023/1
Product Description: Uniaxial Extensometer (Range: 2.000mm, LC: 0.001mm, Class-1 )
Test Parameter:
Linear Measurement
  • Test Points: 0.05, 0.20, 1.00, 1.50, 2.00 mm
    CMC Requirement: coarser than 0.0021 mm
Test Method: Comparison Method as per IS 12872 / ISO 9513 / ASTM E83 / or Technically Equivalent Method
(*) PT round will be completed subjected to at least 7 participants only.
Registration Start Date: Jan-2026
Registration End Date: Jun-2026
Participant Premises Sequential Yes
20 Plan Id: GLMV/P1126/PTC/01/2023/1
Product Description: Linear Variable Differential Transformers (LVDT) (LVDT has the range of 0 to 25 mm with 0.001mm resolution.)
Test Parameter:
Linear Measurement
  • Test Points: 5.1, 10.3, 12.9, 17.6, 20.2 mm
    CMC Requirement: coarser than 0.0016 mm
Test Method: Comparison Method as per ASTM F 2537-06 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 7 participants only.
Registration Start Date: Jan-2026
Registration End Date: Jun-2026
Participant Premises Sequential Yes
21 Plan Id: GLMV/P1148/PTC/01/2023/1
Product Description: Accelerated Curing Tank (ACT) (Range: Up to 100°C & Resolution: 0.1°C )
Test Parameter:
Temperature Error Measurement
  • Test Points: 30.0, 45.0, 60.0, 75.0, 90.0 deg C
    CMC Requirement: coarser than 0.66 deg C
Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Jan-2026
Registration End Date: Jun-2026
PTP Premises Sequential Yes
22 Plan Id: GLMV/P1149/PTC/01/2023/1
Product Description: Curing Tank (Range: Up to 100 °C, Resolution: 0.1°C)
Test Parameter:
Temperature Measurement
  • Test Points: 25.0, 26.0, 27.0, 29.0, 30.0 deg C
    CMC Requirement: coarser than 0.66 deg C
Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Jan-2026
Registration End Date: Jun-2026
PTP Premises Sequential Yes
23 Plan Id: GLMV/P1153/PTC/01/2023/1
Product Description: Thermocouple With Indicator (Range: 200°C to 1500°C, Resolution: 0.001°C, S-Type )
Test Parameter:
Temperature Measurement
  • Test Points: 200, 600, 900, 1200 deg C
    CMC Requirement: Participant can participate having any CMC since assign value of PT Item established directly by NMI.
Test Method: Comparison Method as per ASTM E 220- 13/ EURAMET cg-8 or Technically Equivalent Method.
(*) PT round will be completed subjected to at least 8 participants only.
Registration Start Date: Dec-2025
Registration End Date: Apr-2026
Participant Premises Sequential Yes
24 Plan Id: GLMV/P1140/PTC/01/2023/1
Product Description: Muffle Furnace (Digital Muffle Furnace having the range of 1200 deg C with resolution 0.1°C up to 999.9°C & 1°C from 1000-1200°C.)
Test Parameter:
Temperature Measurement
  • Test Points: 300.0, 500.0, 700.0, 900.0 deg C
    CMC Requirement: coarser than 2.67 deg C
Test Method: Comparison Method as per DKD R5-7 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Oct-2025
Registration End Date: Apr-2026
PTP Premises Sequential Yes
25 Plan Id: GLMV/P1119/PTC/01/2023/1
Product Description: Perforated Test Sieve (Nominal Apperture Size: 20mm)
Test Parameter:
Minimum Aperture Size
  • CMC Requirement: coarser than 0.0113 mm
Maximum Aperture Size
  • CMC Requirement: coarser than 0.0113 mm
Minimum Pitch Size
  • CMC Requirement: coarser than 0.0113 mm
Maximum Pitch Size
  • CMC Requirement: coarser than 0.0113 mm
Test Method: Comparison Method as per IS 460 Part-2: 2020 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Nov-2025
Registration End Date: Apr-2026
Participant Premises Sequential Yes
26 Plan Id: GLMV/P1116/PTC/01/2023/1
Product Description: Cube Mould (Size:- 150*150*150 mm.)
Test Parameter:
Linear Measurement: Length
  • Test Points: 150 mm
    CMC Requirement: coarser than 0.0109 mm
Linear Measurement: Width
  • Test Points: 150 mm
    CMC Requirement: coarser than 0.0109 mm
Linear Measurement: Height
  • Test Points: 150 mm
    CMC Requirement: coarser than 0.0109 mm
Test Method: Comparison Method as per IS 10086: 2021 IS 9669 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 5 participants only.
Registration Start Date: Nov-2025
Registration End Date: May-2026
Participant Premises Sequential Yes
27 Plan Id: GLMV/P1111/PTC/01/2023/1
Product Description: External Micrometer (Digital Micrometer (Range: 25mm, Resolution: 0.001 mm) )
Test Parameter:
Linear Measurement
  • Test Points: 5.1, 10.3, 15, 20.2, 22.8 mm
    CMC Requirement: coarser than 0.00076 mm
Test Method: Comparison Method as per IS 2967: 1983 or Technically Equivalent Method
(*) PT round will be completed subjected to at least 7 participants only.
Registration Start Date: Oct-2025
Registration End Date: Apr-2026
Participant Premises Sequential Yes
(*) mark terms and condition will apply.

Contact Details of PT Scheme:
Name: Mr. Vivek Kumar (PT Coordinator)
Contact No.: 8097457925
Email: ptcoordinator@globallab.co.in

Note: